Livewell pumps
- Hums, no water: the impeller is jammed with a shell, a bait or sea grass. Many livewell pumps have a removable cartridge; pull it and clear it.
- Runs, weak flow: the intake strainer or the thru-hull is fouled, or the pump has lost prime with the boat on the trailer.
- Nothing at all: check the fuse, then the switch, then the connection at the pump. Livewell pumps live in the wettest part of the boat and their connectors corrode first.
- Works on the dock, not underway: aerated water at the intake. The pickup position or a high-speed pickup is the fix, not a new pump.
Macerator pumps
- Runs but will not empty the tank: the tank vent is blocked, or the pump has lost prime. A blocked vent is far more common than people expect.
- Trips the breaker: the pump is jammed or seized. Do not keep resetting it.
- Runs and stops after a few seconds: thermal cutout. The pump is being run dry or is working too hard against a blockage.
- Nothing: the same chain as any pump. Fuse, switch, connection, then the motor.
Before you replace it
Put a meter on the pump wires with the switch on. If there is no voltage at the pump, the pump is not the problem and a new one will not fix it. If there is voltage and the pump does nothing, now you have a dead pump.
When you do replace one, replace the connectors and the section of wire next to it at the same time. That is almost always where the next failure is waiting.
Questions people ask next
Why does my livewell pump work at the dock but not underway?
Air at the intake. At speed the pickup is in aerated water and the pump cannot prime. A high-speed pickup or a better pickup position is the fix, not a new pump.
Why does the macerator trip the breaker?
It is jammed or seized and drawing too much current. Do not keep resetting the breaker; the motor is already working against something. Clear the blockage or replace the pump, and check the tank vent, because a blocked vent makes a macerator work far harder than it should.
How do I test whether a boat pump is getting power?
Put a meter on the two wires at the pump with the switch on. No voltage means the fault is upstream: fuse, switch or a connector. Voltage with no action means the pump itself is dead. That one test prevents most needless pump replacements.